Operation of carbonization furnace

Release date:18,Apr-2023

Back to list
online service

Online customer service 3 seconds response~

Chat Online

Usage of carbonization furnace:

Before using the carbonization furnace, check whether the fan rotates flexibly and smoothly; Whether the condenser is leaking water; Whether the connections between various components are tight, and whether the sealing rock wool between the furnace door and the fire door is sufficient; Then install fuel rods into the furnace, which must be evenly laid flat. After filling, close the furnace door, ignite the fuel in the ignition furnace, start the induced draft fan, close the upper fire door, open the lower fire door, adjust the smoke exhaust valve, and keep the flue unobstructed. If there is smoke, remove the ignition furnace. Secondly, timely control of temperature requires some production experience. Finally, carbonization is completed. After the temperature inside the furnace drops to 100 ℃, the furnace door can be opened. Prepare water in advance, and if there is any charcoal with sparks when removing it, immerse it in water.

79c9f469c2877e34cdd9aa5f079cfc8.jpg

Precautions for carbonization furnace operation:

Usually, before using a carbonization furnace, it is necessary to inspect the equipment first. At this point, it is necessary to check whether the fan of the equipment is flexible and whether the working status of each component is abnormal. Secondly, check the condenser for water leakage. If the condenser leaks, it needs to be repaired in a timely manner. Carbonization equipment needs to be in a sealed state during operation, so workers who have worked on it should also focus on checking whether the sealing effect of each part of the equipment is not good. Among them, the furnace door is a very critical component, and inspection before using the equipment is very important.

During the operation of the carbonization furnace, it is necessary to adjust the valve in a timely manner to keep the valve unobstructed. When smoke begins to form, the ignition device should be removed in a timely manner and the expected temperature effect should be achieved immediately through temperature control. These operating procedures need to be noted, so workers who operate and use carbonization equipment need to master these operating knowledge and equipment application precautions in order to ensure stable operation of the equipment and provide more convenient conditions for production work.


Online messageOnline messageIf you have any questions, please leave a message here to tell us, we will contact you in time!

Service